Media reports / MAGNETIC SELECTION NEWSDry magnetic separator in the process of use should pay attention to
(1) the wear of the cylinder wall of the permanent magnet cylinder, if it is found that the adhesive is seriously worn after falling off, it should be treated or re-hung in time.
(2) If there is any iron block and other debris in the box, it should be removed immediately after discovery.
③ In the case of overheating of motor, CVT and permanent magnet cylinder bearings, the bearing temperature rise shall not exceed 35°C, and the maximum shall not exceed 65°C.
(4) The tension of the transmission belt should be appropriate.
(5) the wear of the belt, found that there is serious wear, should choose the same length of the belt group replacement.
(6) Whether there is enough grease at each lubrication point and whether the oil level of the continuously variable speed is normal. If it is found insufficient, it should be supplemented in time.
The maintenance of permanent magnet dry magnetic separator is a regular work. The quality of maintenance work directly affects the operation rate and service life of permanent magnet dry magnetic separator. In order to find defects and eliminate hidden dangers in time to ensure the normal operation of the machine, in addition to daily maintenance, it is also necessary to stop maintenance regularly (once a month is recommended) to check the important parts such as drum wall, box body, transmission belt, etc., and make detailed records. According to the situation of defects in order of importance, appropriate treatment and arrangement of medium repair and overhaul plan.